Colorimetric Reverse Transcription–Loop-Mediated Isothermal Amplification Assay for Rapid Detection of SARS-CoV-2

Meng Yee Lai Department of Parasitology, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia;

Search for other papers by Meng Yee Lai in
Current site
Google Scholar
PubMed
Close
,
Soo Nee Tang Department of Medical Microbiology, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia

Search for other papers by Soo Nee Tang in
Current site
Google Scholar
PubMed
Close
, and
Yee Ling Lau Department of Parasitology, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia;

Search for other papers by Yee Ling Lau in
Current site
Google Scholar
PubMed
Close

ABSTRACT.

Coronavirus disease 2019 (COVID-19), which is caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), has been spreading rapidly all over the world. In the absence of effective treatments or a vaccine, there is an urgent need to develop a more rapid and simple detection technology of COVID-19. We describe a WarmStart colorimetric reverse transcription–loop-mediated isothermal amplification (RT-LAMP) assay for the detection of SARS-CoV-2. The detection limit for this assay was 1 copy/µL SARS-CoV-2. To test the clinical sensitivity and specificity of the assay, 37 positive and 20 negative samples were used. The WarmStart colorimetric RT-LAMP had 100% sensitivity and specificity. End products were detected by direct observation, thereby eliminating the need for post-amplification processing steps. WarmStart colorimetric RT-LAMP provides an opportunity to facilitate virus detection in resource-limited settings without a sophisticated diagnostic infrastructure.

The outbreak of a cluster of respiratory illness caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has infected millions of people globally. The disease was named coronavirus disease 2019 (COVID-19) and it was declared by the WHO1 as a pandemic as the virus spread rapidly throughout the world. The virus has strong person-to-person transmissibility and is spread through droplets produced from coughing, saliva, and sneezing.2

Early and rapid diagnostic assays for SARS-CoV-2 is important to reduce the spread of this virus because there is currently a lack of effective antiviral drugs. To date, TaqMan probe based-real-time qualitative polymerase chain reaction (PCR) is the most popular molecular diagnostic method used for the detection of SARS-CoV-2. However, real-time qualitative PCR requires expensive equipment and has a long turnover time.3

In an attempt to mitigate this weakness, we developed a faster and visible loop-mediated isothermal amplification (LAMP) assay for the diagnosis of SARS-CoV-2 infection. The LAMP is a simple and rapid detection method that synthesizes a large amount of nucleic acid within 30 minutes without the need for complicated and expensive equipment.

For rapid and direct visualization of the end products in our study, we used a commercially available colorimetric LAMP reagent for the detection of COVID-19 samples. This is a two-color reverse transcription (RT)-LAMP assay protocol for detecting SARS-CoV-2 viral RNA. The inclusion of pH-indicator dye phenol red in the master mix enables a change in color from pink to yellow if a positive amplification occurs. A no-template control was always included.

A total of 57 nasopharyngeal swabs samples from a recent COVID-19 outbreak in Malaysia (March 2020) were obtained from the University of Malaya Medical Center and were examined using the WarmStart colorimetric RT-LAMP assay. The samples were confirmed previously as COVID-19 by real-time RT-PCR prior to using the WarmStart colorimetric RT-LAMP assay. Of 57 samples, 37 tested positive by real-time RT-PCR and 20 tested negative. Ethics approval was obtained from the University of Malaya Medical Research Ethics Committee (202041-8418).

The WarmStart colorimetric RT-LAMP assay was conducted using primers targeted on the RNA-dependent RNA polymerase (RdRp) gene. Primers were designed using Primer-Explorer V4 software (Eiken Chemical Co., Ltd., Tokyo, Japan) based on the SARS-CoV2 RdRp marker (GenBank accession nos. LR757995.1, LR757998.1, and MT192773.1). The LAMP assay was performed in a 25-μL reaction mixture that consisted of 12.5 µL WarmStart colorimetric LAMP 2× master mix (New England Biolabs, Ipswich, MA) at 65°C in a Loopamp Real-Time Turbidimeter LA 500 (Eiken Chemical Co.). Positive and negative reactions were indicated by yellow and pink colors, respectively (Figure 1).

Figure 1.
Figure 1.

Detection of loop-mediated isothermal amplification (LAMP) end product by color changes. (A) Positive amplified LAMP product changed to yellow color. (B) Negative amplified LAMP product remained red. This figure appears in color at www.ajtmh.org.

Citation: The American Journal of Tropical Medicine and Hygiene 105, 2; 10.4269/ajtmh.21-0150

A recombinant plasmid carrying the RdRp gene was constructed to test the analytical sensitivity of the WarmStart colorimetric RT-LAMP assay. RdRp F3 and B3 primers were used to amplify the RdRp gene from a synthetic fragment (Sangon Biotec Co., Ltd., Shanghai, China). PCR conditions were as follows: denaturation at 94°C for 3 minutes, 30 cycles at 94°C for 30 seconds, at 55°C for 30 seconds, and at 72°C for 30 minutes, and a final extension step at 72°C for 10 minutes. The PCR product was then subjected to 2% agarose gel electrophoresis. The amplified gene fragment was purified prior to cloning into the pGEM-T vector (Promega Corporation, Madison, WI) and transformed into TOP10F′ Escherichia coli-competent cells. Recombinant plasmids were extracted using the Qiagen Spin Miniprep kit (Qiagen, Hilden, Germany) and were sent to MyTACG Biosciences Enterprise (Kuala Lumpur, Malaysia) for sequencing to confirm its identity. The pGEM-T vector containing the RdRp insert was linearized by BamHI and transcribed to RNA using RiboMAX™ Large Scale RNA Production Systems (Promega Corporation, Madison, WI) according to the manufacturer’s instructions. The RNA copy number was calculated based on the following formula: copies/µL = 6.02 × 1023 × 10−9 × concentration (ng/µL)/(fragment length × 340).4 Then, 10-fold serial dilutions of the transcribed RNA ranging from 1 × 106 copies/µL to 1 copy/µL were prepared. Results show that the limit of detection of the transcribed RNA was 1 copy/µL.

The specificity of the WarmStart colorimetric RT-LAMP assay was tested using genomic RNA of coronaviruses (HCoV-OC43 and SARS-CoV), adenovirus, human metapneumovirus, influenza A (A/H1pdm2009 and A/H3) and influenza B viruses, parainfluenza virus 3, rhinovirus A, respiratory syncytial virus B, and enterovirus D68. The results show the specificity was 100%.

The clinical sensitivity and specificity of the WarmStart colorimetric RT-LAMP were evaluated using 57 samples collected from the University of Malaya Medical Center. Sensitivity was calculated as (number of true positives)/(number of true positives + number of false negatives); specificity was calculated as (number of true negatives)/(number of true negatives + number of false positives). The WarmStart colorimetric RT-LAMP detected all the real-time RT-PCR positive samples as positive and did not detect any of the real-time RT-PCR negative samples. It had 100% sensitivity and specificity.

Compared with other studies, our study shows that the lowest detection limit of the RT-LAMP assay was 1 copy/µL within 30 minutes by using the RdRp gene as a target. Huang et al.,5 on the other hand, showed that the lowest detection limit of a colorimetric assay was 2 copies/µL within 30 minutes by using the S gene. Their findings also showed that the lowest detection limit for the Orf1ab gene was 20 copies/µL. Baek et al.6 managed to detect the N1 gene down to 100 copies/µL within 30 minutes by using the WarmStart colorimetric RT-LAMP assay.

We evaluated the use, suitability, and advantages of the WarmStart colorimetric RT-LAMP assay for the detection of SARS-CoV-2. Cross-contamination can be reduced because monitoring using the WarmStart colorimetric RT-LAMP assay relies on color changes of the end products. Thus, no post-amplification work such as gel electrophoresis and ethidium bromide gel staining are required. The pH indicator dye was incorporated in the reaction buffer during manufacture, thereby avoiding the need for additional dye for viewing end products after amplification. The risk of carryover contamination was also reduced because the cap of the tube was not opened, which minimizes the opportunity of airborne aerosol being released into surrounding areas.

Some measures of precaution need to be considered when handling RNA samples because they degrade rapidly and need to be “reverse transcripted” to complementary DNA prior to proceeding with any downstream work. The WarmStart colorimetric RT-LAMP assay is a one-step protocol for detecting RNA. Additional reverse transcriptase enzyme did not need to be added to the reaction mixture because it was included in the reaction buffer during manufacture. This is another advantage of this assay. Coupled with these advantages, this reagent has been used by other investigators as well. Ahn et al.7 used this reagent successfully to detect influenza viruses (H1N1, H3N2, and Type B) and avian influenza viruses (H5N1, H5N6, H5N8, and H7N9), with a 98.9% positive rate compared with 92.3% when RT-PCR was used. With this similar reagent, Thi et al.8 achieved 99.5% specificity and 86% sensitivity during their development of a swab-to-RT-LAMP assay for detecting SARS-CoV-2 RNA in clinical samples.

CONCLUSION

The results of our study suggest that the WarmStart colorimetric RT-LAMP assay may provide a rapid, sensitive, and reliable diagnostic method for detecting SARS-CoV-2 without the need for sophisticated equipment. The assay may be used as an initial screening tool, followed by confirmatory laboratory testing such as the conventional real-time RT-PCR method. The WarmStart colorimetric RT-LAMP assay may potentially increase the speed of diagnosis and overcome the rapid spread of SARS-CoV-2.

ACKNOWLEDGMENTS

The following reagent was obtained through the National Institutes of Health Biodefense and Emerging Infections Research Resources Repository, National Institute of Allergy and Infectious Diseases: gamma-irradiated SARS-coronavirus, NR-9547. The American Society of Tropical Medicine and Hygiene has waived the Open Access fee for this article due to the ongoing COVID-19 pandemic.

References

  • 1.

    World Health Organization , 2020. Novel Coronavirus (2019-nCoV) Situation Report, 10. Geneva, Switzerland: WHO. Available at: https://apps.who.int/iris/handle/10665/330775. Accessed May 24, 2021.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 2.

    Shereen MA , Khan S , Kazmi A , Bashir N , Siddique R , 2020. COVID-19 infection: origin, transmission, and characteristics of human coronaviruses. J Adv Res 24: 9198.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 3.

    Lu R , Wu X , Wan Z , Li Y , Zuo L , Qin J , Jin X , Zhang C , 2020. Development of a novel reverse transcription loop-mediated isothermal amplification method for rapid detection of SARS-CoV-2. Virol Sin 35: 344347.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 4.

    Yan C et al.2020. Rapid and visual detection of 2019 novel coronavirus (SARS-CoV-2) by a reverse transcription loop-mediated isothermal amplification assay. Clin Microbiol Infect 26: 773779.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 5.

    Huang WE et al.2020. RT-LAMP for rapid diagnosis of coronavirus SARS-CoV-2. Microb Biotechnol 13: 950961.

  • 6.

    Baek YH et al.2020. Development of a reverse transcription-loop mediated isothermal amplification as a rapid early-detection method for novel SARS-CoV-2. Emerg Microbes Infect 9: 9981007.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 7.

    Ahn SJ et al.2020. Rapid and simple colorimetric detection of multiple influenza viruses infecting humans using a reverse transcriptional loop mediated isothermal amplification (RT-LAMP) diagnostic platform. BMC Infect Dis 19: 676.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 8.

    Thi DVL et al.2020. A colorimetric RT-LAMP assay and LAMP-sequencing for detecting SARS-CoV-2 RNA in clinical samples. Sci Transl Med 12: eabc7075.

Author Notes

Address Correspondence to Yee Ling Lau, Department of Parasitology, Faculty of Medicine, University of Malaya, 50603 Kuala Lumpur, Malaysia. E-mail: lauyeeling@um.edu.my

Financial support: This study was supported by Long Term Research Grant Scheme (LRGS), LRGS/1/2018/UM/01/1/4 (LR002D-2018) from the Ministry of Higher Education, Malaysia.

Authors’ addresses: Meng Yee Lai and Yee Lin Lau, Department of Parasitology, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia, E-mails: mengylai11@yahoo.com and lauyeeling@um.edu.my. Soo Nee Tang, Department of Medical Microbiology, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia, E-mail: tang.soonee@ummc.edu.my.

  • Figure 1.

    Detection of loop-mediated isothermal amplification (LAMP) end product by color changes. (A) Positive amplified LAMP product changed to yellow color. (B) Negative amplified LAMP product remained red. This figure appears in color at www.ajtmh.org.

  • 1.

    World Health Organization , 2020. Novel Coronavirus (2019-nCoV) Situation Report, 10. Geneva, Switzerland: WHO. Available at: https://apps.who.int/iris/handle/10665/330775. Accessed May 24, 2021.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 2.

    Shereen MA , Khan S , Kazmi A , Bashir N , Siddique R , 2020. COVID-19 infection: origin, transmission, and characteristics of human coronaviruses. J Adv Res 24: 9198.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 3.

    Lu R , Wu X , Wan Z , Li Y , Zuo L , Qin J , Jin X , Zhang C , 2020. Development of a novel reverse transcription loop-mediated isothermal amplification method for rapid detection of SARS-CoV-2. Virol Sin 35: 344347.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 4.

    Yan C et al.2020. Rapid and visual detection of 2019 novel coronavirus (SARS-CoV-2) by a reverse transcription loop-mediated isothermal amplification assay. Clin Microbiol Infect 26: 773779.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 5.

    Huang WE et al.2020. RT-LAMP for rapid diagnosis of coronavirus SARS-CoV-2. Microb Biotechnol 13: 950961.

  • 6.

    Baek YH et al.2020. Development of a reverse transcription-loop mediated isothermal amplification as a rapid early-detection method for novel SARS-CoV-2. Emerg Microbes Infect 9: 9981007.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 7.

    Ahn SJ et al.2020. Rapid and simple colorimetric detection of multiple influenza viruses infecting humans using a reverse transcriptional loop mediated isothermal amplification (RT-LAMP) diagnostic platform. BMC Infect Dis 19: 676.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 8.

    Thi DVL et al.2020. A colorimetric RT-LAMP assay and LAMP-sequencing for detecting SARS-CoV-2 RNA in clinical samples. Sci Transl Med 12: eabc7075.

Past two years Past Year Past 30 Days
Abstract Views 0 0 0
Full Text Views 2591 1071 35
PDF Downloads 1218 143 7
 
 
 
 
Affiliate Membership Banner
 
 
Research for Health Information Banner
 
 
CLOCKSS
 
 
 
Society Publishers Coalition Banner
Save