A Sensitive Reverse Transcription Loop-Mediated Isothermal Amplification Assay for Direct Visual Detection of SARS-CoV-2

Yee Ling Lau Department of Parasitology, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia;

Search for other papers by Yee Ling Lau in
Current site
Google Scholar
PubMed
Close
,
Ilyiana Binti Ismail Department of Pathology, Hospital Sungai Buloh, Selangor, Malaysia;

Search for other papers by Ilyiana Binti Ismail in
Current site
Google Scholar
PubMed
Close
,
Nur Izati Binti Mustapa Department of Pathology, Hospital Sungai Buloh, Selangor, Malaysia;

Search for other papers by Nur Izati Binti Mustapa in
Current site
Google Scholar
PubMed
Close
,
Meng Yee Lai Department of Parasitology, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia;

Search for other papers by Meng Yee Lai in
Current site
Google Scholar
PubMed
Close
,
Tuan Suhaila Tuan Soh Department of Pathology, Hospital Sungai Buloh, Selangor, Malaysia;

Search for other papers by Tuan Suhaila Tuan Soh in
Current site
Google Scholar
PubMed
Close
,
Afifah Haji Hassan Department of Pathology, Hospital Sungai Buloh, Selangor, Malaysia;

Search for other papers by Afifah Haji Hassan in
Current site
Google Scholar
PubMed
Close
,
Kalaiarasu M. Peariasamy Clinical Research Centre, Hospital Sungai Buloh, Selangor, Malaysia;

Search for other papers by Kalaiarasu M. Peariasamy in
Current site
Google Scholar
PubMed
Close
,
Yee Leng Lee Clinical Research Centre, Hospital Sungai Buloh, Selangor, Malaysia;

Search for other papers by Yee Leng Lee in
Current site
Google Scholar
PubMed
Close
, and
Pik Pin Goh Institute for Clinical Research (ICR), National Institutes of Health (NIH), Ministry of Health Malaysia, Putrajaya, Malaysia

Search for other papers by Pik Pin Goh in
Current site
Google Scholar
PubMed
Close

ABSTRACT

A simple and rapid reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay was developed for the detection of SARS-CoV-2. The RT-LAMP assay was highly specific for SARS-CoV-2 and was able to detect one copy of transcribed SARS-CoV-2 RNA within 24 minutes. Assay validation performed using 50 positive and 32 negative clinical samples showed 100% sensitivity and specificity. The RT-LAMP would be valuable for clinical diagnosis and epidemiological surveillance of SARS-CoV-2 infection in resource-limited areas as it does not require the use of sophisticated and costly equipment.

The rapid spread of COVID-19 represents a global public health threat with a significant impact on the global economy, health, and many other sectors. COVID-19 is caused by coronavirus called SARS-CoV-2.1 Quantitative reverse transcription PCR (RT-qPCR)2 assays have been developed for the rapid detection of SARS-CoV-2, but they often require costly and sophisticated PCR machines which hamper its application in resource-limited settings.

Loop-mediated isothermal amplification (LAMP) represents a potential alternative for molecular testing in these settings. Loop-mediated isothermal amplification can amplify nucleic acids under isothermal conditions using a simple incubator or water bath with high speed, specificity, and sensitivity. Recently, this assay has been successfully used to detect pathogenic viruses such as Newcastle disease virus, classical swine fever virus, and SARS-CoV-2.3–5 Loop-mediated isothermal amplification is highly specific because of the use of four specific primers (Forward primer [F3], Backward primer [B3], Forward inner primer [FIP], and Backward inner primer [BIP]) that recognize six independent regions of a target DNA fragment. Forward inner primer and BIP bind to four distinct regions of the target fragment. The duration of LAMP reaction can be shortened by the addition of loop primers (loop forward [LF] and loop backward [LB]) and swarm primers (Forward swarm primer [F1S] and Backward swarm primer [B1S]).6 Loop primers targeted between the primering sites of FIP/BIP primers and swarm primers targeted on a region upstream of the FIP/BIP primers recognition sequences on opposite strands (Martineau et al., 2017). This modification has shown to reduce the reaction time and at the same time, increase sensitivity. The primer sequences are shown in Table 1. The reverse transcription LAMP (RT-LAMP) assay was performed in a 12.5-μL reaction mixture that consisted of 4.65 µL RNase-free water, 1X isothermal amplification buffer, 6 mM MgSO4, 1.2 mM deoxyribonucleotide triphosphates 4 U Bacillus stearothermophilus 2.0 WarmStart DNA polymerase, 3 U WarmStart RTx reverse transcriptase (NEB, Ipswich, MA), 0.5 µL RNasin® Ribonuclease Inhibitor (Promega, Madison, WI), 6 µM FIP and BIP primers each, 0.4 µM LF and LB primers each, 0.2 µM F3 and B3 primers each, 1.6 µM F1S and B1S swarm primers each, and 2 µL of RNA template. The reaction mixture was incubated at 65°C in a Loopamp Real-Time Turbidimeter LA 500 (Eiken Chemical Co., Ltd., Taito-ku, Japan). In the present study, a previously developed RT-LAMP5 was optimized to detect SARS-CoV-2 in clinical samples within 24 minutes by additional of swarm primers. The best performance of RT-LAMP reaction was achieved with the eight primer sets (FIP/BIP, F1S/B1S, F3/B3, and LF/LB) with 1.6 µM of each swarm primer concentration. The optimal LAMP reaction was observed at 65°C. Detection of LAMP amplification products was performed by observing the color changes of the reaction tube after the additional of hydroxy naphthol blue (HNB)7 (Figure 1), which reduces the cost and labor of post-amplification analysis.

Table 1

Primers used in this study

PrimerSequence (5′–3′)
Forward inner primerTGGGGTCCATTATCAGACATTTTAGTTTTAGAGTATCATGACGTTCG
Backward inner primerCGAAATGCACCCCGCATTACCCACTGCGTTCTCCATTC
Forward loop primerTGTTCGTTTAGATGAAATC
Backward loop primerTGGTGGACCCTCAGATTCAA
Forward primerGTTGTTCGTTCTATGAAGACT
Backward primerGACGTTGTTTTGATCGCG
Forward swarm primerTTGGGGTCCATTATCAG
Backward swarm primerATCAGCGAAATGCACC
Figure 1.
Figure 1.

Detection of loop-mediated isothermal amplification (LAMP) products by the color change method using hydroxy naphthol blue. (A) The negative LAMP reaction remained in violet color (B), whereas the positive reaction was indicated by a color change from violet to sky blue.

Citation: The American Journal of Tropical Medicine and Hygiene 103, 6; 10.4269/ajtmh.20-1079

The RT-LAMP was highly specific for detecting SARS-CoV-2. The results showed that the amplification product was positive only when SARS-CoV-2 RNA was added. The RNA of other virus strains could not be detected. The specificity of the RT-LAMP assay was determined by using genomic RNA of adenovirus, human metapneumovirus, influenza A (A/H1pdm2009 and A/H3) viruses, influenza B virus, parainfluenza virus 3, rhinovirus A, respiratory syncytial virus B, and enterovirus D68. Results indicate that none of these virus strains was positive.5 The 10-fold serial diluents of SARS-CoV-2 in vitro–transcribed RNAs were used as a template for both RT-LAMP and RT-qPCR amplification. The detection limit of RT-LAMP was one copy and that of RT-qPCR was five copies. When tested with 50 RT-PCR–positive (cycle threshold levels between 21 and 38 cycles) and 32 RT-PCR–negative nasopharyngeal swabs samples collected from a recent COVID-19 outbreak in Malaysia by Hospital Sungai Buloh, Malaysia, RT-LAMP showed a sensitivity and specificity of 100%, with an average incubation time of 24 minutes.

Reverse transcription loop-mediated isothermal amplification assay has been widely developed and used in nucleic acid amplification as it is rapid, simple, sensitive, and specific. Recently, this assay has been successfully used for the diagnosis of pathogenic microorganisms and in drug resistant studies.8,9 To overcome the limitations of RT-qPCR which is costly, we have optimized a previously developed RT-LAMP assay5 by supplementation of swarm primers for the rapid detection of SARS-CoV-2. The swarm primers prime at the F1/B1 sites of the FIP/BIP primer recognition sequences and further enhance the amplification process without complications.6 Following the adding of this primer set, we optimized the combination of primer sets, concentration of swarm primers, and temperature to reduce the detection time. The LAMP reaction was optimized at 65°C using all eight primers together with 1.6 µM of each swarm primer. Reverse transcription loop-mediated isothermal amplification with swarm primers improved average reaction time from 30 to 24 minutes. Meanwhile, the sensitivity of the RT-LAMP assay was evaluated through tenfold serial dilution of transcribed RNA which showed a detection limit of one copy per reaction, supporting the higher sensitivity of this assay than RT-qPCR (five copies) and other RT-LAMP assays developed by Lu et al.10 and Baek et al.,11 which has a detection limit of 118.6 and 100 copies per reaction, respectively. When tested with clinical samples, the RT-LAMP assay developed in this study showed a sensitivity and specificity of 100%. The results promote its application in detecting a low viral load infection. The LAMP approach has been combined with the recombinase polymerase amplification by El-Tholotha et al.12 for the detection of SARS-CoV-2. This study is of greater sensitivity than LAMP alone, but the whole process needs ∼1 hour to complete. On top of that, this assay has not been tested with actual clinical samples.

Given that RT-LAMP is highly sensitive, contamination is a major problem for end point analysis, which required the reaction tube to be opened, which can generate aerosols, such as agarose gel analysis and sequencing. To overcome this problem, we used HNB as a color indicator which resulted in a color change for positive reaction. This is cost-effective and simple to use as described by Goto et al.7

However, the major limitation of this assay compared with RT-qPCR is the complexity of designing LAMP primers. Loop-mediated isothermal amplification requires the design of a set of at least four primers to identify six regions of the target gene to increase the efficiency of the reaction, with the inclusion of two additional swarm primers to accelerate the reaction. As such, primer development could be challenging.

In this study, we optimized a SARS-CoV-2–specific RT-LAMP assay with the inclusion of swarm primers as a rapid, simple, sensitive, and specific molecular test for the detection of SARS-CoV-2. Sensitive and rapid diagnosis assay that can recognize early infection can be very important for control of the disease in affected communities.

ACKNOWLEDGMENTS

We thank the Director General of the Ministry of Health Malaysia for his permission to publish this paper. Publication charges for this article were waived due to the ongoing pandemic of COVID-19.

REFERENCES

  • 1.↑

    World Health Organization, 2020a. WHO Health Emergency Dashboard. Geneva, Switzerland: WHO. Available at: https://extranet.who.int/publicemergency. Accessed August 18, 2020.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 2.↑

    World Health Organization, 2020b. Novel Coronavirus (2019-nCoV) Technical Guidance: Laboratory Testing for 2019-nCoV in Humans. Geneva, Switzerland: WHO. Available at: https://www.fda.gov/media/134922/download. Accessed August 18, 2020.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 3.↑

    Pham HM, Nakajima C, Ohashi K, Onuma M, 2005. Loop-mediated isothermal amplification for rapid detection of Newcastle Disease Virus. J Clin Microbiol 43: 1646–1650.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 4.

    Chen HT, Zhang J, Sun D, Ma L, Liu XT, Cai XP, Liu YS, 2008. Development of reverse transcription loop-mediated isothermal amplification for rapid detection of H9 avian influenza virus. J Virol Methods 151: 200–203.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 5.↑

    Lau YL et al. 2020. Real-time reverse transcription loop-mediated isothermal amplification for rapid detection of SARS-CoV-2. Peer J 8: e9278.

  • 6.↑

    Martineau RL, Murray SA, Ci SF, Gao WM, Chao SH, Meldrum DM, 2017. Improved performance of loop-mediated isothermal amplification assays via swarm priming. Anal Chem 89: 625–632.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 7.↑

    Goto M, Honda E, Ogura A, Nomoto A, Hanaki KI, 2009. Colorimetric detection of loop-mediated isothermal amplification reaction by using hydroxy naphthol blue. Biotechniques 46: 167–172.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 8.↑

    Lau YL, Lai MY, Teoh BT, Abd-Jamil J, Johari J, Sam SS, Tan KK, AbuBakar S, 2015. Colorimetric detection of dengue by single tube reverse-transcription-loop-mediated isothermal amplification. PLoS One 10: e0138694.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 9.↑

    Wu D, Kang J, Li B, Sun D, 2019. Evaluation of the RT-LAMP and LAMP methods for detection of Mycobacterium tuberculosis. J Clin Lab Anal 32: e22326.

  • 10.↑

    Lu RF, Wu XM, Wan ZZ, Li YX, Zuo L, Qin JR, Jin X, Zhang C, 2020. Development of a novel reverse transcription loop-mediated isothermal amplification method for rapid detection of SARS-CoV-2. Virol Sin 35: 344–347.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 11.↑

    Baek YH et al. 2020. Development of a reverse transcription-loop mediated isothermal amplification as a rapid early-detection method for novel SARS-CoV-2. Emerg Microb Infect 9: 998–1007.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 12.↑

    El-Tholotha M, Haim B, Song J, 2020. A single and two-stage, closed-tube, molecular test for the 2019 novel coronavirus (COVID-19) at home, clinic, and points of entry. ChemRxiv. doi: 10.26434/chemrxiv.11860137.

    • PubMed
    • Search Google Scholar
    • Export Citation

Author Notes

Address correspondence to Yee Ling Lau, Department of Parasitology, Faculty of Medicine, University of Malaya, Jalan Lembah Pantai, 50603 Kuala Lumpur, Malaysia. E-mail: lauyeeling@um.edu.my

Authors’ addresses: Yee Ling Lau and Meng Yee Lai, Department of Parasitology, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia, E-mails: lauyeeling@um.edu.my and mengylai11@yahoo.com. Ilyiana Binti Ismail, Nur Izati Binti Mustapa, Tuan Suhaila Tuan Soh, and Afifah Haji Hassan, Department of Pathology, Hospital Sungai Buloh, Selangor, Malaysia, E-mails: ilyiana_banos@yahoo.com, iezat_m@yahoo.com, tuan_suhaila@yahoo.com, and afifah.hassan@moh.gov.my. Kalaiarasu M. Peariasamy and Yee Leng Lee, Clinical Research Centre, Hospital Sungai Buloh, Selangor, Malaysia, E-mails: drkalaiarasu@gmail.com and lee.yeelenglee@hotmail.com. Pik Pin Goh, National Clinical Research Unit, Hospital Kuala Lumpur Jalan Pahang, Kuala Lumpur, Malaysia, E-mail: gohpp@crc.gov.my.

  • Figure 1.

    Detection of loop-mediated isothermal amplification (LAMP) products by the color change method using hydroxy naphthol blue. (A) The negative LAMP reaction remained in violet color (B), whereas the positive reaction was indicated by a color change from violet to sky blue.

  • 1.

    World Health Organization, 2020a. WHO Health Emergency Dashboard. Geneva, Switzerland: WHO. Available at: https://extranet.who.int/publicemergency. Accessed August 18, 2020.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 2.

    World Health Organization, 2020b. Novel Coronavirus (2019-nCoV) Technical Guidance: Laboratory Testing for 2019-nCoV in Humans. Geneva, Switzerland: WHO. Available at: https://www.fda.gov/media/134922/download. Accessed August 18, 2020.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 3.

    Pham HM, Nakajima C, Ohashi K, Onuma M, 2005. Loop-mediated isothermal amplification for rapid detection of Newcastle Disease Virus. J Clin Microbiol 43: 1646–1650.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 4.

    Chen HT, Zhang J, Sun D, Ma L, Liu XT, Cai XP, Liu YS, 2008. Development of reverse transcription loop-mediated isothermal amplification for rapid detection of H9 avian influenza virus. J Virol Methods 151: 200–203.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 5.

    Lau YL et al. 2020. Real-time reverse transcription loop-mediated isothermal amplification for rapid detection of SARS-CoV-2. Peer J 8: e9278.

  • 6.

    Martineau RL, Murray SA, Ci SF, Gao WM, Chao SH, Meldrum DM, 2017. Improved performance of loop-mediated isothermal amplification assays via swarm priming. Anal Chem 89: 625–632.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 7.

    Goto M, Honda E, Ogura A, Nomoto A, Hanaki KI, 2009. Colorimetric detection of loop-mediated isothermal amplification reaction by using hydroxy naphthol blue. Biotechniques 46: 167–172.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 8.

    Lau YL, Lai MY, Teoh BT, Abd-Jamil J, Johari J, Sam SS, Tan KK, AbuBakar S, 2015. Colorimetric detection of dengue by single tube reverse-transcription-loop-mediated isothermal amplification. PLoS One 10: e0138694.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 9.

    Wu D, Kang J, Li B, Sun D, 2019. Evaluation of the RT-LAMP and LAMP methods for detection of Mycobacterium tuberculosis. J Clin Lab Anal 32: e22326.

  • 10.

    Lu RF, Wu XM, Wan ZZ, Li YX, Zuo L, Qin JR, Jin X, Zhang C, 2020. Development of a novel reverse transcription loop-mediated isothermal amplification method for rapid detection of SARS-CoV-2. Virol Sin 35: 344–347.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 11.

    Baek YH et al. 2020. Development of a reverse transcription-loop mediated isothermal amplification as a rapid early-detection method for novel SARS-CoV-2. Emerg Microb Infect 9: 998–1007.

    • PubMed
    • Search Google Scholar
    • Export Citation
  • 12.

    El-Tholotha M, Haim B, Song J, 2020. A single and two-stage, closed-tube, molecular test for the 2019 novel coronavirus (COVID-19) at home, clinic, and points of entry. ChemRxiv. doi: 10.26434/chemrxiv.11860137.

    • PubMed
    • Search Google Scholar
    • Export Citation
Past two years Past Year Past 30 Days
Abstract Views 0 0 0
Full Text Views 1659 349 32
PDF Downloads 1036 95 9
 

 

 

 
 
Affiliate Membership Banner
 
 
Research for Health Information Banner
 
 
CLOCKSS
 
 
 
Society Publishers Coalition Banner
Save