Abstract.

The World Health Organization’s Global Program to Eliminate Lymphatic Filariasis (LF) has reduced LF transmission worldwide, but millions remain affected by filarial lymphedema. Tools for clinically monitoring lymphedema in developing nations are limited. We tested a novel, portable, infrared three-dimensional imaging system (3DIS) against water displacement (WD) and tape measurement of limb circumference (TMLC) among patients with filarial leg lymphedema in Galle, Sri Lanka. Outcomes were accuracy and reproducibility of imaging system measurements. In parallel, we also tested the reproducibility of skin thickness ultrasound (STU) measurements. We examined 52 patients (104 limbs) with lymphedema of stages 0–6 ( = 28, 19, 20, 21, 2, 4, and 10, respectively). 3DIS measurements correlated nearly perfectly with WD ( = 0.9945) and TMLC values ( > 0.9801). The median time required to acquire imaging system measurements for both legs was 2.1 minutes, compared with 17, 7, and 29 minutes, respectively, for WD, TMLC, and STU. Median interexaminer coefficients of variation (CVs) for volume measurements were 1.1% (interquartile range [IQR] 0.5–2.1%) for WD and 1.7% (IQR 1.2–2.4%) for the 3DIS. CVs for circumference measurements were 1.4% (IQR 0.8–2.4%) by TMLC and 1.3% (0.8–1.9%) by 3DIS. Median interexaminer CV for STU was 13.7% (IQR 8.5–21.3%). The portable imaging system noninvasively provided accurate and reproducible limb volume and circumference measurements in approximately 2 minutes per patient. This portable technology has the potential to greatly improve assessment and monitoring of lymphedema in the clinic and in the field.

Loading

Article metrics loading...

The graphs shown below represent data from March 2017
/content/journals/10.4269/ajtmh.17-0504
2017-12-06
2018-12-18
Loading full text...

Full text loading...

/deliver/fulltext/14761645/97/6/tpmd170504.html?itemId=/content/journals/10.4269/ajtmh.17-0504&mimeType=html&fmt=ahah

References

  1. WHO, 2015. 489 Global programme to eliminate lymphatic filariasis: progress report, 2014. Wkly Epidemiol Rec 90: 489504. [Google Scholar]
  2. Ramaiah KD, Ottesen EA, , 2014. Progress and impact of 13 years of the global programme to eliminate lymphatic filariasis on reducing the burden of filarial disease. PLoS Negl Trop Dis 8: e3319. [Google Scholar]
  3. Dreyer G, Addiss D, Dreyer P, Noroes J, , 2002. Basic Lymphedema Management: Treatment and Prevention of Problems Associated with Lymphatic Filariasis. Hollis, NJ: Hollis Pub Co.
  4. Chromy A, Zalud L, Dobsak P, Suskevic I, Mrkvicova V, , 2015. Limb volume measurements: comparison of accuracy and decisive parameters of the most used present methods. Springerplus 4: 707. [Google Scholar]
  5. Warren AG, Brorson H, Borud LJ, Slavin SA, , 2007. Lymphedema: a comprehensive review. Ann Plast Surg 59: 464472. [Google Scholar]
  6. Casley-Smith JR, , 1994. Measuring and representing peripheral oedema and its alterations. Lymphology 27: 5670. [Google Scholar]
  7. Pani SP, Vanamail P, Yuvaraj J, , 1995. Limb circumference measurement for recording edema volume in patients with filarial lymphedema. Lymphology 28: 5763. [Google Scholar]
  8. Mand S, 2012. Doxycycline improves filarial lymphedema independent of active filarial infection: a randomized controlled trial. Clin Infect Dis 55: 621630. [Google Scholar]
  9. Stanton AW, Northfield JW, Holroyd B, Mortimer PS, Levick JR, , 1997. Validation of an optoelectronic limb volumeter (Perometer). Lymphology 30: 7797. [Google Scholar]
  10. Hameeteman M, Verhulst AC, Vreeken RD, Maal TJ, Ulrich DJ, , 2016. 3D stereophotogrammetry in upper-extremity lymphedema: an accurate diagnostic method. J Plast Reconstr Aesthet Surg 69: 241247. [Google Scholar]
  11. Ohberg F, Zachrisson A, Holmner-Rocklov A, , 2014. Three-dimensional camera system for measuring arm volume in women with lymphedema following breast cancer treatment. Lymphat Res Biol 12: 267274. [Google Scholar]
  12. Lu G, DeSouza GN, Armer J, Anderson B, Shyu CR, , 2013. A System for Limb-Volume Measurement using 3D Models from an Infrared Depth Sensor. 2013 IEEE Symposium on Computational Intelligence in Healthcare and e-health (CICARE), 6469.
  13. Moreira R, Magalhães A, Oliveira HP, , 2015. A kinect-based system to assess lymphedema impairments in breast cancer patients. Paredes R, Cardoso JS, Pardo XM, eds. Pattern Recognition and Image Analysis. 7th Iberian Conference, IbPRIA 2015, Santiago de Compostela, Spain, June 17–19, 2015. Cham, Germany: Springer International Publishing, 228236.
  14. WHO ECoF, 1992. Lymphatic Filariasis: The Disease and its Control, Fifth Report of the WHO Expert Committee on Filariasis. Geneva, Switzerland: World Health Organization.
http://instance.metastore.ingenta.com/content/journals/10.4269/ajtmh.17-0504
Loading
/content/journals/10.4269/ajtmh.17-0504
Loading

Data & Media loading...

Supplemental Table and Video

  • Received : 23 Jun 2017
  • Accepted : 14 Aug 2017

Most Cited This Month

This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error