Evaluation of Whole and Purified Hydatid Fluid Antigens in the Diagnosis of Human Hydatidosis by the Immunoelectrophoresis Test

V. M. Varela-Díaz Pan American Zoonoses Center, Pan American Health Organization, World Health Organization, Laboratorio de Inmunología Parasitaria, Hospital de Clínicas, Facultad de Medicina, Casilla 23, Ramos Mejía, Argentina

Search for other papers by V. M. Varela-Díaz in
Current site
Google Scholar
PubMed
Close
,
J. A. Guisantes Pan American Zoonoses Center, Pan American Health Organization, World Health Organization, Laboratorio de Inmunología Parasitaria, Hospital de Clínicas, Facultad de Medicina, Casilla 23, Ramos Mejía, Argentina

Search for other papers by J. A. Guisantes in
Current site
Google Scholar
PubMed
Close
,
M. I. Ricardes Pan American Zoonoses Center, Pan American Health Organization, World Health Organization, Laboratorio de Inmunología Parasitaria, Hospital de Clínicas, Facultad de Medicina, Casilla 23, Ramos Mejía, Argentina

Search for other papers by M. I. Ricardes in
Current site
Google Scholar
PubMed
Close
,
L. A. Yarzábal Pan American Zoonoses Center, Pan American Health Organization, World Health Organization, Laboratorio de Inmunología Parasitaria, Hospital de Clínicas, Facultad de Medicina, Casilla 23, Ramos Mejía, Argentina

Search for other papers by L. A. Yarzábal in
Current site
Google Scholar
PubMed
Close
, and
E. A. Coltorti Pan American Zoonoses Center, Pan American Health Organization, World Health Organization, Laboratorio de Inmunología Parasitaria, Hospital de Clínicas, Facultad de Medicina, Casilla 23, Ramos Mejía, Argentina

Search for other papers by E. A. Coltorti in
Current site
Google Scholar
PubMed
Close
Restricted access

Whole sheep hydatid cyst fluid (WHF) and purified hydatid fluid antigens (PHF) were evaluated in the immunoelectrophoresis (IEP) test for the diagnosis of human hydatid disease. A higher sensitivity was obtained using the PHF than with the WHF antigen but false positive results were observed with the former in 22.4% of the 102 non-hydatid sera examined. Using the presence of arc 5 as the criterion of positivity however, no false positives were observed in non-hydatid sera with the WHF antigen. It is postulated that the number of bands other than arc 5 may be of value in the diagnosis of hydatid disease by the IEP test, in cases where this diagnostic arc is absent.

Author Notes

Fellow, Pan American Health Organization.

Short-term consultant, Pan American Health Organization.

Past two years Past Year Past 30 Days
Abstract Views 1561 1179 401
Full Text Views 5 1 0
PDF Downloads 6 2 0
 

 

 

 
 
Affiliate Membership Banner
 
 
Research for Health Information Banner
 
 
CLOCKSS
 
 
 
Society Publishers Coalition Banner
Save