New Thick-Film Technique for Malaria Diagnosis

Use of Saponin Stromatolytic Solution for Lysis

Joel Umlas Mount Auburn Hospital, Harvard Medical School, Cambridge, Massachusetts 02138

Search for other papers by Joel Umlas in
Current site
Google Scholar
PubMed
Close
and
Jalmer N. Fallon Mount Auburn Hospital, Harvard Medical School, Cambridge, Massachusetts 02138

Search for other papers by Jalmer N. Fallon in
Current site
Google Scholar
PubMed
Close
Restricted access

The many Americans returning from areas of endemic malaria require that most clinical laboratories be proficient in preparing blood films for examination for malaria parasites. Adequate thick films challenge laboratories not ordinarily involved in these studies. We describe a new method for preparing thick films, using saponin stromatolytic solution as the lysing agent. This method, combined with Wright stain or Wright-Giemsa mixtures, gives results equal to or superior to conventional methods of lysing combined with longer Giemsa staining times; it is also more suitable to the clinical laboratory not involved in malaria screening or numerous cases of malaria. The reagents required are inexpensive and used in almost all clinical laboratories. Slides prepared with saponin lysis require less time to prepare, especially when stained with automatic slide stainers. They contain less background debris, making examination easier and more accurate. When used as described, the saponin does not appear to lyse plasmodia.

Author Notes

Present address: U. S. Reynolds Army Hospital, Fort Sill, Oklahoma 73503.