1921
Volume 85, Issue 5
  • ISSN: 0002-9637
  • E-ISSN: 1476-1645

Abstract

Abstract.

Malaria control can be improved by rapid, sensitive, low-cost detection of infection. Several such strategies are being pursued. Rapid diagnostic tests can detect infections at parasite densities above 200 μL. Polymerase chain reaction methods can detect low parasite densities, but are slow and prone to contamination under field conditions. Methods that detect hemozoin presence in blood have been proposed as alternatives for rapid detection of infection. In this study, we used a benchtop nuclear magnetic resonance (NMR) device to detect hemozoin. This device could be deployed in malaria-endemic settings. We measured synthetic hemozoin in phosphate-buffered saline and malaria parasites in human blood. The NMR detected hemozoin in suspensions of 4 ng μL and parasites at densities of 8,000–10,000 μL (0.2% parasitemia). Thus, our preliminary NMR approach, although providing very rapid measurements, is unlikely to achieve the required sensitivity and specificity for malaria diagnosis, unless a preliminary concentration step is performed.

Loading

Article metrics loading...

/content/journals/10.4269/ajtmh.2011.11-0299
2011-11-01
2017-11-24
Loading full text...

Full text loading...

/deliver/fulltext/14761645/85/5/815.html?itemId=/content/journals/10.4269/ajtmh.2011.11-0299&mimeType=html&fmt=ahah

References

  1. Hommel M, , 2008. Towards a research agenda for global malaria elimination. Malar J 7 (Suppl 1): S1.[Crossref]
  2. Craig MH, Bredenkamp BL, Williams CH, Rossouw EJ, Kelly VJ, Kleinschmidt I, Martineau A, Henry GF, , 2002. Field and laboratory comparative evaluation of ten rapid malaria diagnostic tests. Trans R Soc Trop Med Hyg 96: 258265.[Crossref]
  3. Baird JK, , 2011. Eliminating malaria–all of them. Lancet 376: 18831885.[Crossref]
  4. Newman DM, Heptinstall J, Matelon RJ, Savage L, Wears ML, Beddow J, Cox M, Schallig HD, Mens PF, , 2008. A magneto-optic route toward the in vivo diagnosis of malaria: preliminary results and preclinical trial data. Biophys J 95: 9941000.[Crossref]
  5. Mens PF, Matelon RJ, Nour BY, Newman DM, Schallig HD, , 2010. Laboratory evaluation on the sensitivity and specificity of a novel and rapid detection method for malaria diagnosis based on magneto-optical technology (MOT). Malar J 9: 207.[Crossref]
  6. Bejon P, Andrews L, Hunt-Cooke A, Sanderson F, Gilbert SC, Hill AV, , 2006. Thick blood film examination for Plasmodium falciparum malaria has reduced sensitivity and underestimates parasite density. Malar J 5: 104.[Crossref]
  7. McNamara DT, Thomson JM, Kasehagen LJ, Zimmerman PA, , 2004. Development of a multiplex PCR-ligase detection reaction assay for diagnosis of infection by the four parasite species causing malaria in humans. J Clin Microbiol 42: 24032410.[Crossref]
  8. Moody A, , 2002. Rapid diagnostic tests for malaria parasites. Clin Microbiol Rev 15: 6678.[Crossref]
  9. Jaramillo M, Bellemare MJ, Martel C, Shio MT, Contreras AP, Godbout M, Roger M, Gaudreault E, Gosselin J, Bohle DS, Olivier M, , 2009. Synthetic Plasmodium-like hemozoin activates the immune response: a morphology—function study. PLoS ONE 4: e6957.[Crossref]
  10. Trager W, Jensen JB, , 1976. Human malaria parasites in continuous culture. Science 193: 673675.[Crossref]
  11. Krantz A, , 1997. Red cell-mediated therapy: opportunities and challenges. Blood Cells Mol Dis 23: 5868.[Crossref]
  12. McKenzie FE, Prudhomme WA, Magill AJ, Forney JR, Permpanich B, Lucas C, Gasser RA, Jr Wongsrichanalai C, , 2005. White blood cell counts and malaria. J Infect Dis 192: 323330.[Crossref]
  13. Smith DW, , 1980. The molecular biology of mammalian hemoglobin synthesis. Ann Clin Lab Sci 10: 116122.
  14. Hanscheid T, Egan TJ, Grobusch MP, , 2007. Hemozoin: from melatonin pigment to drug target, diagnostic tool, and immune modulator. Lancet Infect Dis 7: 675685.[Crossref]
  15. Karl S, David M, Moore L, Grimberg BT, Michon P, Mueller I, Zborowski M, Zimmerman PA, , 2008. Enhanced detection of gametocytes by magnetic deposition microscopy predicts higher potential for Plasmodium falciparum transmission. Malar J 7: 66.[Crossref]
  16. Karl S, Davis TM, St-Pierre TG, , 2009. A comparison of the sensitivities of detection of Plasmodium falciparum gametocytes by magnetic fractionation, thick blood film microscopy, and RT-PCR. Malar J 8: 98.[Crossref]
  17. Romagosa C, Menendez C, Ismail MR, Quintó L, Ferrer B, Alonso PL, Ordi J, , 2004. Polarization microscopy increases the sensitivity of hemozoin and Plasmodium detection in the histological assessment of placental malaria. Acta Trop 90: 277284.[Crossref]
  18. Scholl PF, Kongkasuriyachai D, Demirev PA, Feldman AB, Lin JS, Sullivan DJ, Jr Kumar N, , 2004. Rapid detection of malaria infection in vivo by laser desorption mass spectrometry. Am J Trop Med Hyg 71: 546551.
http://instance.metastore.ingenta.com/content/journals/10.4269/ajtmh.2011.11-0299
Loading
/content/journals/10.4269/ajtmh.2011.11-0299
Loading

Data & Media loading...

  • Received : 10 May 2011
  • Accepted : 30 Jul 2011

Most Cited This Month

This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error