Abstract

Abstract.

Thick film, the standard diagnostic procedure for malaria, is not always ordered promptly. A failsafe diagnostic strategy using an XE-2100 analyzer is proposed, and for this strategy, malaria diagnostic models for the XE-2100 were developed and tested for accuracy. Two hundred eighty-one samples were distributed into , , and acute febrile syndrome groups for model construction. Model validation was performed using 60% of malaria cases and a composite control group of samples from AFS and healthy participants from endemic and non-endemic regions. For two observer-dependent models (accuracy = 95.3–96.9%), one non–observer-dependent model using built-in variables (accuracy = 94.7%), and one non–observer-dependent model using new and built-in variables (accuracy = 96.8%) were developed. For two non–observer-dependent models (accuracies = 85% and 89%) were developed. These models could be used by health personnel or be integrated as a malaria alarm for the XE-2100 to prompt early malaria microscopic diagnosis.

Loading

Article metrics loading...

/content/journals/10.4269/ajtmh.2010.09-0464
2010-03-01
2017-09-20
Loading full text...

Full text loading...

/deliver/fulltext/14761645/82/3/402.html?itemId=/content/journals/10.4269/ajtmh.2010.09-0464&mimeType=html&fmt=ahah

References

  1. Newman RD, Parise ME, Barber AM, Steketee RW, , 2004. Malaria-related deaths among U.S. travelers, 1963–2001. Ann Intern Med 141: 547555.[Crossref]
  2. Lema OE, Carter JY, Nagelkerke N, Wangai MW, Kitenge P, Gikunda SM, Arube PA, Munafu CG, Materu SF, Adhiambo CA, Mukunza HK, , 1999. Comparison of five methods of malaria detection in the outpatient setting. Am J Trop Med Hyg 60: 177182.
  3. Mendelow BV, Lyons C, Nhlangothi P, Tana M, Munster M, Wypkema E, Liebowitz L, Marshall L, Scott S, Coetzer TL, , 1999. Automated malaria detection by depolarization of laser light. Br J Haematol 104: 499503.[Crossref]
  4. Fourcade C, Casbas MJ, Belaouni H, Gonzalez JJ, Garcia PJ, Pepio MA, , 2004. Automated detection of malaria by means of the haematology analyser Coulter GEN.S. Clin Lab Haematol 26: 367372.[Crossref]
  5. Huh HJ, Oh GY, Huh JW, Chae SL, , 2008. Malaria detection with the Sysmex XE-2100 hematology analyzer using pseudoeosinophilia and abnormal WBC scattergram. Ann Hematol 87: 755759.[Crossref]
  6. Yan F, Dai Y, Zhang Z, Wan H, , 2008. The correlation of abnormal information in Sysmex hematology analyzers XE-2100 and XS-1000i with diagnosis of Plasmodium infection. Sysmex Journal International 18: 5053.
  7. Walters J, Garrity P, , 2000. Performance evaluation of the Sysmex XE-2100 hematology analyser. Lab Hematol 6: 8392.
  8. Grobusch MP, Hanscheid T, Kramer B, Neukammer J, May J, Seybold J, Kun JF, Suttorp N, , 2003. Sensitivity of hemozoin detection by automated flow cytometry in non- and semi-immune malaria patients. Cytometry B Clin Cytom 55: 4651.[Crossref]
  9. Huh J, Jung J, Yoon H, Chung W, , 2005. Pseudoeosinophilia associated with malaria infection determined in the Sysmex XE-2100 hematology analyzer. Ann Hematol 84: 400402.[Crossref]
  10. Park GB, Cha YJ, , 2006. Three cases of pseudoeosinophilia associated with malaria determined in the Sysmex XE-2100 automated hematology analyzer. Korean J Lab Med 26: 7780.[Crossref]
  11. Dirección Seccional de Salud de Antioquia, 2006. Events of Public Health Interest—Antioquia 2006. Available at: http://www.dssa.gov.co/htm/event_1.html. Accessed November 1, 2008.
  12. Rutjes AW, Reitsma JB, Vandenbroucke JP, Glas AS, Bossuyt PM, , 2005. Case-control and two-gate designs in diagnostic accuracy studies. Clin Chem 51: 13351341.[Crossref]
  13. Peduzzi P, Concato J, Kemper E, Holford TR, Feinstein AR, , 1996. A simulation study of the number of events per variable in logistic regression analysis. J Clin Epidemiol 49: 13731379.[Crossref]
  14. Bain B, Chiodini P, England J, Bailey J, , 1997. The laboratory diagnosis of malaria. Clin Lab Haematol 19: 165170.[Crossref]
  15. Garvey B, Mahon A, McTaggart P, Parker-Williams J, , 2003. MHRA Evaluation: Sysmex XE-2100 Haematology Analyser. Norwich, United Kingdom: Crown.
  16. Matsumoto H, , 1999. The technology of reagents in the automated hematology analyzer Sysmex XE-2100TM—red fluorescence reaction. Sysmex Journal International 9: 179185.
  17. Ruzicka K, Veitl M, Thalhammer-Scherrer R, Schwarzinger I, , 2001. The new hematology analyzer Sysmex XE-2100: performance evaluation of a novel white blood cell differential technology. Arch Pathol Lab Med 125: 391396.
  18. Kumar A, Yerneni LK, , 2009. Semi-automated relative quantification of cell culture contamination with mycoplasma by Photoshop-based image analysis on immunofluorescence preparations. Biologicals 37: 5560.[Crossref]
  19. Landis JR, Koch GG, , 1977. The measurement of observer agreement for categorical data. Biometrics 33: 159174.[Crossref]
  20. Hanscheid T, Valadas E, Grobusch MP, , 2000. Automated malaria diagnosis using pigment detection. Parasitol Today 16: 549551.[Crossref]
  21. Briggs C, Da Costa A, Freeman L, Aucamp I, Ngubeni B, Machin SJ, , 2006. Development of an automated malaria discriminant factor using VCS technology. Am J Clin Pathol 126: 691698.[Crossref]
  22. Hanscheid T, Langin M, Lell B, Potschke M, Oyakhirome S, Kremsner PG, Grobusch MP, , 2008. Full blood count and haemozoin-containing leukocytes in children with malaria: diagnostic value and association with disease severity. Malar J 7: 109.[Crossref]
  23. Padial MM, Subirats M, Puente S, Lago M, Crespo S, Palacios G, Baquero M, , 2005. Sensitivity of laser light depolarization analysis for detection of malaria in blood samples. J Med Microbiol 54: 449452.[Crossref]
  24. Pinter E, Szabo O, Tdorova R, Varnai Z, Banhegyi D, , 2007. Relapse of Plasmodium vivax and recrudescence of Plasmodium malariae malaria as detects by Sysmex XE 2100 fully automated blood cell analyzer. Sysmex Journal International 17: 102105.
  25. Rowan RM, Linssen J, , 2005. A picture is worth a thousand words: XE-2100 and falciparum malaria. Sysmex Journal International 15: 2738.
  26. Landis JR, Koch GG, , 1977. An application of hierarchical kappa-type statistics in the assessment of majority agreement among multiple observers. Biometrics 33: 363374.[Crossref]
  27. Sysmex Corporation, 2006. Fluorescence Differentiation Supports Malaria Diagnosis. Sysmex Europe GMBH, Norderstedt, Germany. 111.
  28. Nguyen PH, Day N, Pram TD, Ferguson DJ, White NJ, , 1995. Intraleucocytic malaria pigment and prognosis in severe malaria. Trans R Soc Trop Med Hyg 89: 200204.[Crossref]
  29. Hosmer DW, Lemeshow S, Hosmer DW, Lemeshow S, , 2000. Assessing the fit of the model. , eds. Applied Logistic Regression. New York: Wiley-Interscience Publication, 160163.[Crossref]
  30. van Vianen PH, van Engen A, Thaithong S, van der Keur M, Tanke HJ, van der Kaay HJ, Mons B, Janse CJ, , 1993. Flow cytometric screening of blood samples for malaria parasites. Cytometry 14: 276280.[Crossref]
  31. Saito-Ito A, Akai Y, He S, Kimura M, Kawabata M, , 2001. A rapid, simple and sensitive flow cytometric system for detection of Plasmodium falciparum . Parasitol Int 50: 249257.[Crossref]
http://instance.metastore.ingenta.com/content/journals/10.4269/ajtmh.2010.09-0464
Loading
/content/journals/10.4269/ajtmh.2010.09-0464
Loading

Data & Media loading...

Supplementary Data

Supplementary Material

  • Received : 10 Aug 2009
  • Accepted : 15 Dec 2009

Most Cited This Month

This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error