Abstract

Abstract

A rapid diagnostic test for detection of microfilaremia using a microhematocrit tube precoated with acridine orange (the Quantitative Buffy Coat [QBC® tube) was compared with a conventional 50 µl-thick blood film (TF) in 119 volunteers in an area of Recife, Brazil that was endemic for . Both the QBC and the TF techniques were 100% specific, and thus positive predictive values were equal at 100% for each technique in all subjects studied. Both techniques had equal negative predictive values of 100% in subjects with microfilarial counts > 100 per milliliter (mf/ml). Counts < 20 mf/ml are below a cutoff equal to the calculated limit of sensitivity of each of the two techniques. For those individuals with counts between 20 and 99 mf/ml, negative predictive values were, for practical diagnostic purposes, equivalent at 97.5% for the QBC technique and 99.0% for the TF. Because the QBC technique has predictive values as high as conventional TF, the convenience and rapidity of the technique will make the QBC technique a desirable alternative diagnostic method in those clinical settings where the equipment is available. A positive result will be available in less than six min after obtaining the specimen in individuals with counts < 100 mf/ml, and individuals with lower or no microfilaremia will have a result within 6–12 min.

Loading

Article metrics loading...

/content/journals/10.4269/ajtmh.1992.47.787
1992-12-01
2017-09-23
Loading full text...

Full text loading...

http://instance.metastore.ingenta.com/content/journals/10.4269/ajtmh.1992.47.787
Loading

Most Cited This Month

This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error