1921
Volume 88, Issue 6
  • ISSN: 0002-9637
  • E-ISSN: 1476-1645

Abstract

Abstract.

Recent studies using an internal transcribed spacer (ITS)-based real-time polymerase chain reaction (PCR) for the detection of DNA in urine samples has shown high sensitivity and specificity when performed on controls and known microscopy-positive samples. In this study, using 730 urine samples collected from children in five primary schools from different communities in the Greater Accra region of Ghana, specific detection of DNA showed excellent sensitivity of 100% and 85.2% in urines with > 50 eggs/10 mL urine and ≤ 50 eggs/10 mL of urine, respectively. Additionally, -specific DNA was amplified in 102 of 673 samples in which eggs could not be detected with microscopy. Taking microscopy and/or PCR-positive samples as true positives, the negative predictive value calculated was 94.6–100% for each school sampled as compared with 54.3–95.7% using microscopy. This ITS-based real-time PCR proves to be a powerful tool in epidemiological surveys of schistosomiasis providing more precise and sensitive results than microscopy.

Loading

Article metrics loading...

/content/journals/10.4269/ajtmh.12-0571
2013-06-05
2017-11-21
Loading full text...

Full text loading...

/deliver/fulltext/14761645/88/6/1028.html?itemId=/content/journals/10.4269/ajtmh.12-0571&mimeType=html&fmt=ahah

References

  1. McManus DP, Loukas A, , 2008. Current status of vaccine for schistosomiasis. Clin Microbiol Rev 21: 225242.[Crossref]
  2. Gryseels B, Polman K, Clerinx J, Kestens L, , 2006. Human schistosomiasis. Lancet 368: 11061118.[Crossref]
  3. Feldmeier H, Poggensee G, , 1993. Diagnostic techniques in schistosomiasis control: a review. Acta Tropica 52: 205220.[Crossref]
  4. Lengeler C, Utzinger J, Tanner M, , 2002. Questionnaires for rapid screening of schistosorniasis in sub-Saharan Africa. Bull World Health Organ 80: 235242.
  5. ten Hove RJ, Verweij JJ, Vereecken K, Polman K, Dieye L, van Lieshout L, , 2008. Multiplex real-time PCR for the detection and quantification of Schistosoma mansoni and S. haematobium infection in stool samples collected in northern Senegal. Trans R Soc Trop Med Hyg 102: 179185.[Crossref]
  6. van Dam GJ, Wichers JH, Ferreira TM, Ghati D, van Amerongen A, Deelder AM, , 2004. Diagnosis of schistosomiasis by reagent strip test for detection of circulating cathodic antigen. J Clin Microbiol 42: 54585461.[Crossref]
  7. Stothard JR, Kabatereine N, Tukahebwa EM, Kazibwe F, Rollinson D, Mathieson W, Webster JP, Fenwick A, , 2006. Use of circulating cathodic antigen (CCA) dipsticks for detection of intestinal and urinary schistosomiasis. Acta Trop 97: 219228.[Crossref]
  8. Verweij JJ, Brienen EA, Ziem J, Yelifari L, Polderman AM, van Lieshout L, , 2007a. Simultaneous detection and quantification of Ancylostoma duodenale, Necator americanus, and Oesophagostomum bifurcum in fecal samples using multiplex real-time PCR. Am J Trop Med Hyg 77: 685690.
  9. Verweij JJ, Ten Hove R, Brienen EA, van Lieshout L, , 2007b. Multiplex detection of Enterocytozoon bieneusi and Encephalitozoon spp. in fecal samples using real-time PCR. Diagn Microbiol Infect Dis 57: 163167.[Crossref]
  10. Barber KE, Mkoji GM, Loker ES, , 2000. PCR-RFLP analysis of The ITS2 region to identify Schistosoma haematobium and S. bovis from Kenya. Am J Trop Med Hyg 62: 434440.
  11. Abbasi I, King CH, Sturrock RF, Kariuki C, Muchiri E, Hamburger J, , 2007. Differentiation of Schistosoma haematobium from related schistosomes by PCR amplifying an inter-repeat sequence. Am J Trop Med Hyg 76: 950955.
  12. Espy MJ, Uhl JR, Sloan LM, Buckwalter SP, Jones MF, Vetter EA, Yao JDC, Wengenack NL, Rosenblatt JE, Cockerill FR, Smith TF, , 2006. Real-time PCR in clinical microbiology: applications for routine laboratory testing. Clinical Microbiology 19: 165256.[Crossref]
  13. Klein D, , 2002. Quantification using real-time PCR technology: applications and limitations. Trends Mol Med 8: 257260.[Crossref]
  14. Verweij JJ, Blange RA, Templeton K, Schinkel J, Brienen EA, van Rooyen MA, van Lieshout L, Polderman AM, , 2004. Simultaneous detection of Entamoeba histolytica, Giardia lamblia and Cryptosporidium parvum in fecal samples using multiplex real-time PCR. J Clin Microbiol 3: 12201223.[Crossref]
  15. Obeng BB, Aryeetey YA, de Dood CJ, Amoah AS, Larbi IA, Deelder AM, Yazdanbakhsh M, Hartgers FC, Boakye DA, Verweij JJ, van Dam GJ, van Lieshout L, , 2008. Application of a circulating-cathodic-antigen (CCA) strip test and real-time PCR, in comparison with microscopy, for the detection of Schistosoma haematobium in urine samples from Ghana. Ann Trop Med Parasitol 102: 625633.[Crossref]
  16. Ibironke OA, Phillips AE, Garba A, Lamine SM, Shiff C, , 2011. Diagnosis of Schistosoma haematobium by detection of specific DNA fragments from filtered urine samples. Am J Trop Med Hyg 84: 9981001.[Crossref]
  17. Ibironke O, Koukounari A, Asaolu S, Moustaki I, Shiff C, , 2012. Validation of a new test for Schistosoma haematobium based on detection of Dra1 DNA fragments in urine: evaluation through latent class analysis. PLoS Negl Trop Dis 6: 1464.[Crossref]
http://instance.metastore.ingenta.com/content/journals/10.4269/ajtmh.12-0571
Loading
/content/journals/10.4269/ajtmh.12-0571
Loading

Data & Media loading...

  • Received : 13 Sep 2012
  • Accepted : 11 Dec 2012

Most Cited This Month

This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error