AJTMH Tropical Medicine and Hygiene News
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am. J. Trop. Med. Hyg., 47(4), 1992, pp. 463-469
Copyright © 1992 by The American Society of Tropical Medicine and Hygiene

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Van Lieshout, L.
Right arrow Articles by Deelder, A. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Van Lieshout, L.
Right arrow Articles by Deelder, A. M.

Improved Diagnostic Performance of the Circulating Antigen Assay in Human Schistosomiasis by Parallel Testing for Circulating Anodic and Cathodic Antigens in Serum and Urine

Lisette Van Lieshout, Niels De Jonge, Nabil A. El Masry, Moustafa M. Mansour, Frederik W. Krijger AND Andre M. Deelder
U. S. Naval Medical Research Unit No. 3, Cairo, Egypt; Laboratory of Parasitology, University of Leiden, The Netherlands

Serum and urine levels of two Schistosoma circulating antigens, the circulating anodic antigen (CAA) and the circulating cathodic antigen (CCA), were determined by monoclonal antibody-based enzyme-linked immunosorbent assays in 56 Egyptian patients infected with S. mansoni and in 12 patients infected with both S. mansoni and S. haematobium. Both CAA and CCA could be specifically demonstrated in 82% and 88% of the serum samples and in 88% and 87% of the urine samples, respectively. While complete specificity was maintained, sensitivity was increased to a range of 91–98% by parallel use of the two circulating antigen assays, i.e., an individual with a positive titer for at least one of the assays was considered to be infected. A combination of CAA and CCA determinations in urine samples only resulted in a sensitivity of 94%. However, the highest sensitivity was achieved when the serum-CCA assay was combined with the urine-CCA assay (98%) or with the urine-CAA assay (97%). Sensitivity could not be increased further by combining more than two tests. A significant correlation was demonstrated between the level of circulating antigen and the number of parasite eggs in feces in each of the four assays. In addition, the levels of CAA and CCA in serum and urine were significantly correlated with each other. Our results indicate that diagnosis of schistosome infections by detection of circulating antigens can be significantly improved by parallel testing for multiple antigens.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1992 by the American Society of Tropical Medicine and Hygiene.