AJTMH Transactions of the Royal Society of Tropical Medicine and Hygiene
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am. J. Trop. Med. Hyg., 44(6), 1991, pp. 609-622
Copyright © 1991 by The American Society of Tropical Medicine and Hygiene

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hill, S. M.
Right arrow Articles by Crampton, J. M
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hill, S. M.
Right arrow Articles by Crampton, J. M

A Comparison of Non-Radioactive Labeling and Detection Systems with Synthetic Oligonucleotide Probes for the Species Identification of Mosquitoes in the Anopheles Gambiae Complex

Susannah M. Hill, Rachel Urwin AND Julian M Crampton
Wolfson Unit of Molecular Genetics, Liverpool School of Tropical Medicine, Liverpool, United Kingdom

Different non-radioactive probe labeling and detection systems were used with pAnaI, a species-specific oligonuleotide probe that distinguishes male Anopheles gambiae and An. arabiensis mosquitoes. Comparisons have been made between the performance of each technique with respect to sensitivity and specificity against DNA dot-blots and mosquito squashes. Their relative costs, economy, and ease of use were analyzed in an attempt to develop an appropriate non-radioactive system for use in the field.

Enzyme-labeled probes that were detected directly by label activity proved more suitable than probes requiring reporter molecules for detection. Binding of reporter molecules to mosquito squashes caused the appearance of false positives and, in addition, their binding to nylon filters caused high background coloration.

Chemiluminescent detection provided an attractive alternative to colorimetric detection. Both systems analyzed were rapid, simple, and economic. However, less severe treatment of filters was required for reprobing with chemiluminescence. The greatest sensitivity achieved was with chemiluminescent detection in which the limit of detection was 0.15 ng of target DNA. This study suggests that a synthetic DNA probe coupled to a chemiluminescent detection system should provide a sufficiently simple, sensitive, and reliable technique for insect vector identification in the field.