AJTMH Tropical Medicine and Hygiene News
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am. J. Trop. Med. Hyg., 35(3), 1986, pp. 565-570
Copyright © 1986 by The American Society of Tropical Medicine and Hygiene

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Weil, G. J.
Right arrow Articles by Jain, D. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Weil, G. J.
Right arrow Articles by Jain, D. C.

Detection of Circulating Parasite Antigen in Bancroftian Filariasis by Counterimmunoelectrophoresis

G. J. Weil*, H. Kumar, S. Santhanam, K. V. P. Sethumadhavan AND D. C. Jain
* Department of Medicine, Washington University School of Medicine, St. Louis, Missouri 63110 and Helminthology Division, National Institute of Communicable Diseases, Delhi and Calicut, India

We used counterimmunoelectrophoresis (CIEP) with rabbit antibodies to Dirofilaria immitis and Brugia malayi to detect soluble filarial antigen in sera collected in a Wuchereria bancrofti-endemic area in South India. Filarial antigen was detected in 38 of 38 sera from microfilaremic patients, 3 of 48 sera from amicrofilaremic patients with lymphatic pathology, and 3 of 5 sera from former microfilaria carriers with negative blood examinations 6 months or more after diethylcarbamazine therapy. One of 32 endemic control sera, 0 of 35 nonendemic sera, and 0 of 20 B. malayi sera were positive. Antigenemia was equally detectable in sera collected at night or during the day (when microfilariae are absent from the blood). Parasite antigen was also detected in the urine of patients with positive serum tests. Antibodies to circulating filarial antigen (also detected by CIEP) were absent in all but 2 antigen-positive sera but present in 22 of 45 antigen-negative sera from clinical filariasis patients and in 9 of 31 antigen-negative sera from endemic controls. Parasite antigen detection by CIEP appears to be a sensitive, specific, and practical diagnostic test for active W. bancrofti infection.

Accepted for publication January 6, 1986.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1986 by the American Society of Tropical Medicine and Hygiene.