AJTMH HINARI
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am. J. Trop. Med. Hyg., 28(6), 1979, pp. 933-936
Copyright © 1979 by The American Society of Tropical Medicine and Hygiene

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Spencer, H. C.
Right arrow Articles by Skinner, J. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Spencer, H. C.
Right arrow Articles by Skinner, J. C.

The Enzyme-Linked Immunosorbent Assay (Elisa) for Malaria

II. Comparison with the Malaria Indirect Fluorescent Antibody Test (IFA)*

Harrison C. Spencer, William E. Collins AND Jimmie C. Skinner
Bureau of Tropical Diseases, Center for Disease Control, Public Health Service, U.S. Department of Health, Education, and Welfare, Atlanta, Georgia 30333

To compare the micro-enzyme-linked immunosorbent assay (ELISA) done with cultured Plasmodium falciparum as antigen with the indirect fluorescent antibody test (IFA), 261 sera collected in Vietnam and 351 samples eluted from filter papers collected in Honduras were examined by both methods of measuring antibody to P. falciparum. Thick blood films were also examined from persons sampled in Honduras. Discordance between the two tests was observed in 23.0% of the Vietnam sera and in 29.4% of the samples from Honduras. The major differences observed occurred in younger persons (<30 years in the Vietnam specimens and <16 years of age in those from Honduras); in these age groups seropositivity rates by ELISA were significantly higher than those found by IFA. However, even in older persons in whom the seropositivity rates observed with the two tests were similar, many of the specimens were positive by one test but not both. Fifteen persons had slide-demonstrated infection with P. falciparum; all 15 were positive by IFA (reciprocal titer >=20) but only 12 were positive (>=80) by the ELISA. Two of 7 children aged 1–5 years with P. falciparum infections had a negative ELISA test, as did 1 of 6 children 6–15 years of age. These results suggest the measurement of both shared and dissimilar antibodies by the two serologic tests. Further work is necessary to determine why the ELISA is negative in some persons with slide-proven infections.

Accepted for publication April 7, 1979.


* Address reprint requests to: Bureau of Tropical Diseases, Center for Disease Control, 1600 Clifton Road, N.E., Atlanta, Georgia 30333.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1979 by the American Society of Tropical Medicine and Hygiene.